Indoor Modular MV Metal-Clad AIS (Single bar/Double bar)

Property Specification

Type: Metal-Clad Air-Insulated Medium-Voltage Switchgear (AIS) / Modular Indoor Power Distribution System

Features: Featuring a modular metal-clad structure with fully segregated power compartments and an integrated low-voltage compartment, this system supports single and double busbar configurations with full front-access operation. Designed for high operational safety, the system includes internal arc classification (IAC AFLR), metallic safety shutters, comprehensive mechanical and electrical interlocking, and top-mounted arc pressure relief ducts. The platform supports vacuum or SF6 circuit breakers, vacuum contactors, load-break switches, fast-acting earthing switches, and electrolytic copper busbars, offering flexible options for protection, control, and sensor integration.

Applications: Designed for main and auxiliary power substations, power generation facilities, and critical utility networks. It provides reliable power control in demanding heavy-industry sectors including oil and gas, petrochemicals, mining, metallurgy, paper, cement, automotive, textiles, quarrying, and food processing. It is also used in specialized, high-reliability environments such as marine vessels, offshore facilities, seismic zones, and nuclear facilities.

Description

Technical Comparison Matrix

Performance Characteristic / Parameter Medium-Voltage Air-Insulated Switchgear Technical Specifications
System Operating Voltage Rating 7.2 kV – 12 kV – 17.5 kV – 24 kV (up to 27.6 kV)
AC Power-Frequency Withstand Voltage (1 min)

7.2 kV Class: 20 kV

12 kV Class: 28 kV

17.5 kV Class: 38 kV (42 kV for high-dielectric variants)

24 kV Class: 50 kV

Impulse Withstand Voltage (BIL Peak)

7.2 kV Class: 60 kVp

12 kV Class: 75 kVp

17.5 kV Class: 95 kVp

24 kV Class: 125 kVp

Operating Frequency 50 Hz / 60 Hz
Short-Time Withstand Current Capacity

3-Second Rating: Up to 50 kA (7.2–17.5 kV) | Up to 31.5 kA (24 kV) (25 kA in double-busbar arrangement)

1-Second Rating: Up to 63 kA (7.2–17.5 kV) (4-second withstand options available)

Dynamic Peak Making Current Up to 164 kA (7.2–17.5 kV) | Up to 80 kA (24 kV)
Internal Arc Classification (IAC AFLR)

1-Second Arc Withstand: Up to 50 kA (7.2–17.5 kV) | Up to 31.5 kA (24 kV) (25 kA for double busbar)

0.5-Second Arc Withstand: Up to 63 kA (7.2–17.5 kV)

Extended Capacity: Back-to-back duplex arrangements support up to 40/50 kA

Main Busbar Continuous Current Rating (40°C Ambient) Up to 4000 A (7.2–17.5 kV) | Up to 2500 A / 3150 A (24 kV) (4000 A option available)
Feeder and Breaker Current Ratings (Natural Cooling)

7.2–17.5 kV Feeder Ratings: 630 A, 1250 A, 1600 A, 2000 A, 2500 A, 3150 A, 4000 A

24 kV Feeder Ratings: 630 A, 1250 A, 1600 A, 2000 A, 2300 A, 2500 A

Vacuum Contactor Bay Rating: 400 A

Breaker Current Ratings (Forced Ventilation)

7.2–17.5 kV Class: 3600 A / 4000 A

24 kV Class: 2500 A / 3150 A

Enclosure Footprint and Structural Dimensions

12 kV / 17.5 kV Class: Depth: 2021 mm | Height: 2200–2595 mm (depending on low-voltage compartment) | Widths: 650 mm, 800 mm, 1000 mm

24 kV Class: Depth: 2570 mm | Height: 2400–2720 mm | Widths: 800 mm, 1000 mm